  1. Building a three tier brew stand with Unistrut - Homebrew Talk

    Jul 3, 2007 · I could use Unistrut Product Group or Unistrut Product Group I planned on a three tier verticle tower..with square frames off of the main pole for three burners..it seems simple but wanted …

  2. Uni-strut and clamps used as fire sprinkler pipe hangers

    Nov 30, 2006 · WE are seeing more and more cases of unistrut type systems fastening sprinkler piping to building structure. If oriented so that piping is not hanging down against the clamp, the shear or …

  3. Strength of unistrut section | Eng-Tips

    Sep 9, 2004 · I been trying to figure out the strength of a channel shape unistrut bar bolted on a rolling load table, which will be subjected to a concentrated load applied through a ball screw. Would some …

  4. NFPA #13, Trapeze Hangers & Unistrut. | Eng-Tips

    May 23, 2008 · I would also note that unistrut (generic) is NOT listed in any NFPA "tables". So while you see NFPA 13 showing examples of how to determine the section moduls for and angle iron trapeze …

  5. Unistrut Properties Calculation | Eng-Tips

    Aug 11, 2009 · I have a project in Los Angeles in which I have specified a considerable amount of unistrut. I specified the unistrut based on the published allowable values in the Unistrut catalog. LA …

  6. Unistrut Weld Detail | Eng-Tips

    Feb 12, 2019 · What do you guys think about this detail? The legs of the unistrut are facing downwards. The load is only about 150bs. The existing unistruts are already welded in this manner so I am trying …

  7. Unistrut Connection Capacity for General Fittings | Eng-Tips

    Mar 17, 2015 · I am putting together some drawings for a multi-discipline utility rack and I'm using Unistrut tracks and fittings. Their engineering catalog shows beam and column capacities for their …

  8. Unistrut Yield Strength | Eng-Tips

    Nov 14, 2016 · Unistrut reported to me that their Unistrut steel is 33 ksi steel that has been cold rolled to 42 ksi. Does that happen because of compression during the cold rolling process? If not, how, then is …

  9. Unistrut in Torsion | Eng-Tips

    Jun 10, 2025 · Unistrut is setup so that local buckling is probably a non-issue. I certainly don't go out of my way to use unistrut in torsion for primary loads but, for small stuff, I'm sure it works. .unistrut is …

  10. P1000 Unistrut | Eng-Tips

    Nov 11, 2016 · I need to support equipment from the underside of a hollowcore precast concrete roof. The vendor must support their equipment from P1000 Unistrut. The Unistrut engineering is by …