About 59 results
Open links in new tab
  1. What is a dielectric and what are the types of dielectric materials

    Nov 11, 2019 · Dielectric materials can be used for insulation and electrical energy storage. What is the purpose of a dielectric The main purpose of a dielectric is to control the flow of current between the …

  2. What are the different methods of Transformer Oil Testing?

    Jul 25, 2022 · Dielectric Breakdown Voltage (BDV Test): TEST: With this test, the insulating oil’s dielectric strength is evaluated; in other words, we measure the voltage at which the oil fails …

  3. Level measurement using Radar technique - AutomationForum

    Mar 24, 2018 · the probe tube. When a radar pulse reaches a liquid surface that has a higher dielectric constant than the air in the process tank, the pulse is reflected back to the electronic unit. A high …

  4. Proximity detection using capacitance & inductive sensors

    Apr 13, 2018 · C =Ak/d where, C = capacitance (Farads) k = dielectric constant A = area of plates d = distance between plates (electrodes) In the sensor the area of the plates and distance between them …

  5. What are the electrical methods of level measurement?

    Dec 19, 2020 · Displacer Type Level measurement – Leveltrol Laser level transmitter Float level detector Interface level measurement techniques Calibration of Dp level transmitter at the field Level …

  6. Guided Wave Radar Level Transmitters: Complete Troubleshooting ...

    Jun 11, 2025 · Fix common Guided Wave Radar level transmitter issues probe wear, foam interference, signal errors with expert troubleshooting tips and best practices.

  7. Date Design & Selection Identify medium type (liquid, slurry, foam, vaporizing, solid). Determine dielectric constant suitability. Assess turbulence, boiling, frothing conditions. Check environmental …

  8. Ensure difference ≥ recommended by manufacturer. Dielectric Constant (for RF/Capacitance) Obtain dielectric values of both phases if using capacitance technology. Interface Layer Thickness Confirm if …

  9. Rod-Type GWR Installation Suitable for liquids with dielectric constants ≥1.8; range up to 6 meters. Dual-Cable GWR Installation For low dielectric constant liquids or light powders; range up to 30 …

  10. Hybrid Level Measurement: Capacitance + Guided Wave Radar

    Sep 26, 2025 · Noisy signals: Avoid agitator zones and strengthen grounding. Check the dielectric entries again for calibration drift. Why Hybrid Capacitance + GWR is the Future One of the most …